接通电源8秒后正常灯闪动
The normal light flashes 8 seconds after the power is turned on
1、相位有误
1. Phase error
2、线路断相,或保险丝断
2. The line is out of phase, or the fuse is out
1、将三相电的任意两条相线对调
1. Exchange any two phase lines of three-phase electricity
2、接通断相的相线、更换保险丝
2. Connect the broken phase line and replace the fuse
接通电源所有功能皆不能动作
All functions cannot operate when the power is turned on
1、按钮开关的停(T)、上行(SJ)、下行(XJ)开关未按要求接成常开触点方式
1. The stop (T), up (SJ) and down (XJ) switches of the button switch are not connected to the normally open contact mode as required
2、上限位和下限位开关未按要求接成常闭触点方式
2. The upper and lower limit switches are not connected into normally closed contact as required
1、按要求将按钮开关的停(T)、上行(SJ)、下行(XJ)开关接成常开触点方式
1. Connect the stop (T), up (SJ) and down (XJ) switches of the button switch to the normally open contact mode as required
2、按要求将上限位和下限位开关接成常闭触点方式
2. Connect the upper and lower limit switches into normally closed contact mode as required
基本操作正常,在把编程开关SW1(SW2)拨至“OFF”状态时,门自动下行。(正常时门应自动上行至上限位)
The basic operation is normal. When the programming switch SW1 (SW2) is turned to "off", the door will automatically go down. (normally, the door should automatically go up to the upper limit)
1、上限位和下限位控制线接反
1. The upper limit and lower limit control lines are connected reversely
2、电机线接反
2. Reverse connection of motor line
1、将上限位和下限位控制线对调
1. Exchange the upper limit and lower limit control lines
2、将电机线的任意两条线对调
2. Exchange any two lines of the motor line