防火卷帘门几种情况的调试过程
防火卷帘门是现代高层建筑中不可缺少的防火设施,除具备普通门的作用外,具有防火、隔烟、抑制火灾蔓延、保护人员疏散的特殊功能,广泛应用于高层建筑、大型商场等人员密集的场合。下面
济南防火卷帘门安装维修人员来讲讲防火卷帘门的几种情况的调试过程。
Fireproof rolling shutter door is an indispensable fire prevention facility in modern high-rise buildings. In addition to the function of ordinary door, it has the special functions of fire prevention, smoke separation, fire prevention and evacuation protection, and is widely used in high-rise buildings, large shopping malls and other crowded places. Next, the installation and maintenance personnel of Jinan fireproof rolling shutter door will talk about the debugging process of several situations of the fireproof rolling shutter door.
防火卷帘门正反转怎么调?
How to adjust the positive and negative rotation of fire shutter door?
防火卷帘门正反转只需把零线火线交换一下。
The positive and negative rotation of the fireproof rolling shutter door only needs to exchange the zero line and live line.
防火卷帘门在操作运用进程中,操作人员不得私自分开操作地址,应亲密留意启闭状况和执行状况,在启闭时卷帘下面禁绝有人站立、走动。在运用进程中一旦发现异常状况应立刻接纳紧要办法,割断输入电源,扫除毛病。
During the operation and application of the fireproof rolling shutter door, the operator shall not separate the operating address without permission, but shall pay close attention to the opening and closing conditions and execution conditions. No one is allowed to stand or walk under the rolling shutter when opening and closing. In the process of application, once abnormal conditions are found, emergency measures should be taken immediately to cut off the input power supply and eliminate the problems.
防火卷帘门应树立按期保护准则,并做好每樘卷帘的保护记载任务,立案存档。长时间不启闭的卷帘半年需保护一次,内容为消弭尘圾,涂刷油漆,对传动部分的链轮滚子链加光滑油生对等。
The fire rolling shutter door shall be protected on schedule, and the protection record task of each rolling shutter shall be completed and filed. The roller shutters that have not been opened and closed for a long time shall be protected once every six months. The contents are to eliminate dust, paint, and add smooth oil to the sprocket roller chain of the transmission part.
防火卷帘的调试具体步骤?
What are the specific steps for debugging the fire shutter?
1、检查线路正确无误后接通电源,按手动按钮盒上的上升键,使卷帘运行至顶部,然后关闭电源;
1. After checking that the circuit is correct, turn on the power, press the up button on the manual button box to make the roller shutter run to the top, and then turn off the power;
2、中位设置:将SW2拨至ON位,打开电源,按停止键,卷帘停止并记录中停位;
2. Middle position setting: turn SW2 to ON, turn on the power, press the stop button, the roller shutter stops and records the middle position;
3、下位设置:按下降键,卷帘开始下行,再按下停止键或运行至低位后,卷帘停止;
3. Lower position setting: press the down key, the roller shutter starts to go down, and then press the stop key or run to the low position, the roller shutter stops;
4、结束设置:关闭电源,将SW2拨回OFF位后重新打开电源,控制器进入正常运行状态。
4. End setting: turn off the power, turn SW2 back to OFF and turn on the power again, and the controller will enter into normal operation state.
Before the operation inspection of the fire rolling shutter door, attention should be paid to the following aspects, such as power on function, fault alarm function, fire alarm function, manual control function, automatic control function, dead weight drop and other functions. For safety, I hope you can pay more attention and come here http://www.jnyuqilin.com Read more!