您知道防火卷帘的正确控制方法吗?

来源:http://www.jnyuqilin.com/  发布时间:2023-06-29 16:45:16

烟雾探测器与烟雾探测器的结合,从控制方法上保证了防火卷帘迫降的可靠性。在多个防火卷帘处,一些设计单位在每个卷帘处设置烟雾探测器或温度探测器。当探测器移动时,防火卷帘迫降。
The combination of Smoke detector and Smoke detector ensures the reliability of fire shutter forced landing from the control method. Some design units set Smoke detector or temperature detector at each of the multiple fire shutter. When the detector moves, the fire shutter makes a forced landing.
或者防火卷帘旁边的任何探测器接到信号后,卷帘全部迫降至地面。这种控制方法也是不合理的。为了及时控制火势,防止火灾蔓延到其他部位,减少火灾损失,防火卷帘应能时关闭。那么您知道防火卷帘的正确控制方法吗?下面济南防火卷帘门安装维修人员为您讲解:
Or after any detector next to the fire shutter receives a signal, all the curtains will be forced to land to the ground. This control method is also unreasonable. In order to control the fire in a timely manner, prevent the fire from spreading to other parts, and reduce fire losses, the fire shutter should be able to close promptly. Do you know the correct control method for fire resistant rolling shutters? The installation and maintenance personnel of Jinan fire Roller shutter will explain to you:
1、当防火分区内的任何一个火灾探测器检测到火灾信号时,防火分区内的所有防火卷帘都会同时迫降。
1. When any fire detector in the fire compartment detects a fire signal, all fire rolling shutters in the fire compartment will make a forced landing at the same time.
2、如果安装在疏散走道上的防火卷帘安装在防火分区内,应在卷帘两侧附近安装温度探测器,或在防火分区内增加几个温度探测器。这样既能有效地将火势控制在一定范围内,又能防止走道上的防火卷帘过早下降,影响人员疏散。
2. If the fire shutter installed on the evacuation aisle is installed in the fire compartment, temperature detectors should be installed near both sides of the shutter, or several temperature detectors should be added in the fire compartment. This not only effectively controls the fire within a certain range, but also prevents the fire shutter on the aisle from falling too early and affecting personnel evacuation.
济南防火卷帘门安装维修
3、自动扶梯处防火卷帘的迫降方式应采用“两步迫降”,避免自动扶梯上的人员因防火卷帘过早迫降而无法及时安全疏散到楼层。
3. The forced landing method of the fire resistant roller shutter at the escalator should adopt a "two-step forced landing" to prevent personnel on the escalator from being unable to evacuate safely to the floor in a timely manner due to the early forced landing of the fire resistant roller shutter.
4、毫无疑问,防火卷帘的防火分隔功能可以科学合理地利用控制探测器的消防设计方案,使建筑消防设施的维护管理更加完善,从而正确保证防火卷帘门的功能。
4. There is no doubt that the fire separation function of the fireproof rolling shutter can scientifically and reasonably use the fire protection design scheme of the control detector to make the maintenance and management of the building's fire protection facilities more perfect, so as to correctly ensure the function of the fireproof Roller shutter.
防火卷帘的正确控制方法相关事项就讲解到这里了,希望您看完之后能够有一个好的使用,更多关于防火卷帘门的疑惑或者需求,就来我们网站http://www.jnyuqilin.com进行咨询了解吧!
So far are the matters related to the correct control method of the fireproof rolling shutter. I hope you can have a good use after reading it. For more questions or needs about the fireproof Roller shutter, please come to our website http://www.jnyuqilin.com Consult and learn more!